Search the forum,

primary

A set of primary colors consists of colorants or colored lights that can be mixed in varying amounts to produce a gamut of colors. This is the essential method used to create the perception of a broad range of colors in, e.g., electronic displays, color printing, and paintings. Perceptions associated with a given combination of primary colors can be predicted by an appropriate mixing model (e.g., additive, subtractive) that reflects the physics of how light interacts with physical media, and ultimately the retina.
Primary colors can also be conceptual (not necessarily real), either as additive mathematical elements of a color space or as irreducible phenomenological categories in domains such as psychology and philosophy. Color space primaries are precisely defined and empirically rooted in psychophysical colorimetry experiments which are foundational for understanding color vision. Primaries of some color spaces are complete (that is, all visible colors are described in terms of their primaries weighted by nonnegative primary intensity coefficients) but necessarily imaginary (that is, there is no plausible way that those primary colors could be represented physically, or perceived). Phenomenological accounts of primary colors, such as the psychological primaries, have been used as the conceptual basis for practical color applications even though they are not a quantitative description in and of themselves.
Sets of color space primaries are generally arbitrary, in the sense that there is no one set of primaries that can be considered the canonical set. Primary pigments or light sources are selected for a given application on the basis of subjective preferences as well as practical factors such as cost, stability, availability etc.
The concept of primary colors has a long, complex history. The choice of primary colors has changed over time in different domains that study color. Descriptions of primary colors come from areas including philosophy, art history, color order systems, and scientific work involving the physics of light and perception of color.
Art education materials commonly use red, yellow, and blue as primary colors, sometimes suggesting that they can mix all colors. From the perspective of modern color science, no set of real colorants or lights can mix all possible colors.

View More On Wikipedia.org
  1. S

    Primary Circuit Backflow in Solid Fuel / Oil Fired system

    Hi Question on how best to design/solve back flow in a Solid Fuel Primary circuit. This is happening when the fire is not lighting and the oil fired boiler is operating into the common dual coil copper cylinder causing the idle stove coil to heat and thus starting back-flow in its circuit...
  2. A

    F&E teed in to primary flow

    VENTED MULTIFUEL STOVE HEATING SYSTEM WITH MANIFOLD and RADIATORS AND STOREAGE TANK. the circulator pump is in the return primary line after the manifold for rads. and after the return outlet from storage tank pushing direct back to stove boiler. I have just bought...
  3. S

    Ideal Icos HE18 no display?

    hi my Ideal Icos boiler has recently stoped working, there is no lights on the display and there is 240v supply to it and no fuses have blown, ANY IDEAS?? I'm thinking the worst and i think the pcb has gone, but what would cause this to go?:banghead:​
  4. V

    Gravity Flow On Fully Pumped System

    I'm trying to cure a fully-pumped central heating system where the radiators become warm when only the hot water is turned on. This has always been the case ever since the customer moved in. The three port has AB on the left, A to the top and B to the bottom. I was wondering if it's possible...
  5. F

    No hot water

    Hi, I have a gas heated hot water system with a hot water storage tank. It was making a loud noise when hot water tap was switched on and during the week the flexible hose and expansion vessle were replaced with a fixed cooper pipe. Since then the heating of the water has been tempremental...
  6. N

    no circulation gravity primary (semi grav)

    Have fitted new gravity cylinder to old oil fired potterton boiler 15 years old approx.it has 1inch coil inside to match old.the old cylinder was repalced as leaking at seam.There was a pump added to the primary which was removed when fitting new cylinder as I was told this made no difference to...
  7. M

    Primary flow/return to heat generator, unvented cylinder????

    Hi Guys, first post so be gentle. I am by no means a plumber but i do a bit of labouring for a guy who is a plumber, now hes normally pretty good and i like to think i know quite a bit about heating systems etc, but this one has caught us both out. Basically we are converting a system boiler...
  8. N

    pump query

    hi all, A very simple question for most of you but want to check first - not seen the job yet. The pump is a wilo pump on a gravity fed system with a potterton boiler that keeps locking out. This pump is making a gurgling noise when the hot water is boosted, not when the CH is run. Is this...
  9. S

    Halstead ace

    HI i have a problem with my halstead ace boiler. for CH it is always on low flame and only ch is luke warm. hot water is ok on high flame ,any ideas ?
  10. H

    Alpha CD18R problems

    I'm desperate for help and advice I have a Alpha CD18R.... 4 weeks ago (01/11/10) the boiler stopped working and A&B lights were flashing simultaneously. An engineer visited and said we needed a new PCB. The PCB was changed but the lights still flashed; (note: the PCB board was a different...
  11. B

    my boiler wont shut off

    HI, i have a 4 year old worcester bosch greenstar 28i junior combi boiler, when in heating mode the boiler does not cut out and in it just keeps running. thought the problem could be the radio controlled themostat, took it out -no difference, just using the control knob - set it to 4 the...
  12. P

    Anyone experienced with Worcester Greenster HE Combi

    As above, customer reports that when he opens hot water tap boiler rockets up to 90 odd degrees and locks out. Now he says heating is messing about as well. he said boiler had no pressure so topped up to 1.5 and just before its locking out its going up to 3/3.5 bar. Im thinking primary side...
  13. G

    Asked to install flueless gas fire

    Hi Been asked to install flueless gas fire. Just wondering how many of you install these? I gather that the customer would be using it alot in the winter. Aware of vent/room sizes, but still concerned of the safety of these, if they are not serviced regulary. Thanks
  14. S

    new gas run

    today did a new gas run ,customer asked to reconnect existing gas appliances i refused to do it as !gas hob did not have isolating valve ,sign of burn on taps ,primary air port partly block with sh''''t ignition button missing!so ID i thought boiler flue less then 300 mm from internal...
  15. R

    Annoying rumbling noise

    Hi, about six months ago a plumber installed a new Albion ultraseel 180 litre cylinder. The information on the commissioning information says I have a primary open vented boiler. The mains pressure is 3 bar, and a strainer has been fitted. The installler set the water temp. at 60 degrees, i...
  16. K

    airlock on combi boiler primary circuit?

    right ive got a problem after draining and filling a combi heating circuit to change a faulty rad valve. ive never had an airlock before on combi systems, but anyway the problem is that after all rads bled, all work as normal apart from one on the ground floor which only gets luke warm...
  17. J

    vokera compact 29he: DHW ok/ CH cuts out after 10mins???

    After any advise, been to look at vokera compact 29HE fault. No MI present. Hot water is ok and heating works fine for about 10mins, then boiler goes back into stanby. No lockout or red/amber led. Green light flashes faster. You can then turn off/on and will repeat the cycle. On first look...
  18. C

    Ideal miniHE - DHW excessive temp on primary circuit (lights) after plumbing work....

    Hi all Can anyone help? My boiler: Ideal C24/C28 mini HE. 3 years old. Draining the system down to add the rad, the water was nice and clear though we are in a hard water area. 3/4 days ago a gas safe plumber extended my gas feed to my kitchen for a new range and extended the central...
  19. L

    Single Pipe System Radiators

    Hi all, I have been asked to rerplace some radiators in a old house which has a single pipe radiator system in place. The Client has purchased his nice shiny radiators and Honeywell TRVs and new lock shields. Questions The old radiators are top fed and low return, can the new radiators...
  20. T

    Pressure increase?

    Hi all, This might be really obvious but would appreciate your thoughts. Over the last few weeks I have noticed an increase in pressure on the primary circuit of my Halstead Finest. Reset a week ago and still increasing about half bar/week. I'm assuming that the likely candidate is the filler...