Search the forum,

primary

A set of primary colors consists of colorants or colored lights that can be mixed in varying amounts to produce a gamut of colors. This is the essential method used to create the perception of a broad range of colors in, e.g., electronic displays, color printing, and paintings. Perceptions associated with a given combination of primary colors can be predicted by an appropriate mixing model (e.g., additive, subtractive) that reflects the physics of how light interacts with physical media, and ultimately the retina.
Primary colors can also be conceptual (not necessarily real), either as additive mathematical elements of a color space or as irreducible phenomenological categories in domains such as psychology and philosophy. Color space primaries are precisely defined and empirically rooted in psychophysical colorimetry experiments which are foundational for understanding color vision. Primaries of some color spaces are complete (that is, all visible colors are described in terms of their primaries weighted by nonnegative primary intensity coefficients) but necessarily imaginary (that is, there is no plausible way that those primary colors could be represented physically, or perceived). Phenomenological accounts of primary colors, such as the psychological primaries, have been used as the conceptual basis for practical color applications even though they are not a quantitative description in and of themselves.
Sets of color space primaries are generally arbitrary, in the sense that there is no one set of primaries that can be considered the canonical set. Primary pigments or light sources are selected for a given application on the basis of subjective preferences as well as practical factors such as cost, stability, availability etc.
The concept of primary colors has a long, complex history. The choice of primary colors has changed over time in different domains that study color. Descriptions of primary colors come from areas including philosophy, art history, color order systems, and scientific work involving the physics of light and perception of color.
Art education materials commonly use red, yellow, and blue as primary colors, sometimes suggesting that they can mix all colors. From the perspective of modern color science, no set of real colorants or lights can mix all possible colors.

View More On Wikipedia.org
  1. S

    Worcester primary hex leaking?

    I read a thread today that had a couple of members saying they have come across lots of leaking worcester hex's whats the best way to check im thinking isolate the boiler and leave the sump cover off tgen check for pressure drop and water in the sump? I am the unfortunate owner of a Woosy Tosch...
  2. B

    warmflow boiler - primary heat exchanger of the appliance corroded

    I have a warmflow boiler and it is giving me headaches. It is less than 3 years old and I am now told that the primary heat exchanger has been corroded and is leaking - and the boiler cannot be fixed only replaced. I am told the corrosion has taken place because we have been topping it up with...
  3. R

    converting from open vent to sealed primary

    Hello folks, converting open vent system to sealed heating system (hot water to remain vented) - the boiler is fine to convert (glowworm ultimate), as is cylinder. I know it needs expansion vessel, safety valve, gauge, filling loop etc. Initial query: can the safety valve go in the airing...
  4. T

    2 hot water cylinders on a solid fuel primary circuit

    I'm wanting to run 2 hot water cylinders from my solid fuel boiler , instead of buying a very expensive large one . I already have the copper cylinders. I would like to give one priority over the other, and rely on gravity only , if possible . Is it ok to run a 28mm hot feed up , which is teed...
  5. M

    Bypass on primary flow and return to indirect cylinder

    Hi if fitting a bypass on the primary flow and return to an indirect hot water cylinder I know this needs to be positioned between the pump and zone valves as once the zone valve shuts off the pump will have an over run. Is this correct? Also do people now fit automatic bypasses instead of a...
  6. D

    F+E tank with no vent

    hi i was just wondering if this is normal or it it was a mistake. the F+E tank never had a vent on it, we drained it down and it took 2 hours to get up and running. some of the air was coming though the cold feed to the primaries to the tank. I've had a look though my college books but can't...
  7. S

    Warmflow 70-90 hot water problems

    Hi all, first time poster here so hope you can help! Got called to a boiler breakdown today with the customer complaining of lukewarm hot water. Had a look at the boiler and it is a warmflow 70-90 combi (with the flexible braided pipes inside) I've seen before with them the flexible pipes being...
  8. B

    Airlocks in boiler primary flow and return??

    Hi there, I'm going to install an oil fired boiler soon, and the primary flow and return rises from the floor standing boiler and then travels across the top of the kitchen and then down the wall into the cylinder cupboard and up into the mid positioned valve. Its an open vented system, so can...
  9. S

    ALPHA CD24C Primary pressure switch leaking

    hi all newbie here. so i have just put the central heating on and ten minutes later hear dripping water from boiler, alpha cd24c 5year-9mnth old removed front casing to see water coming out of the pressure primary switch housing (not its seating) so a couple of questions. 1 think i got extra...
  10. E

    No hot water - Primary flow switch/diaphragm

    Hi all, Got a Halstead Ace High with the pin on the primary flow switch not coming out far enough to switch hot water on - haven't got money for a plumber so I opened the switch and placed the mechanism closer to the pin so that it made contact and switched water light and boiler light on when...
  11. B

    What are the extra inlet/outlets?

    Hi, came across this cylinder today! Customer asked what the two outlets were for. I didn't really know so thought I would seek some advice. Sort of established that the 15mm on the left is a hot water draw off but not sure about the 22mm above the primary. Hope someone can help :-)
  12. P

    Vaillant Primary Heat Exchangers & Blockages

    Are any other Gas/Heating engineers having problems with blocked primary heat exchangers on Vaillant boilers, even on new installations that have been chemically flushed and have filters/dirt seperators protecting the new boiler/s ? We are prodominantly a mechanical installation company...
  13. L

    Out of my depth please help!!!

    3 rd time ive tried to post this... so this is the really really short version Is there a 3 port valve that only has 3 wires (l,n,e) on it made by honeywell please guys that has a relay in the wiring centre?
  14. S

    Aerjec removal

    Hi all, Quick query, if you were to remove an aerjec and re-pipe without it would the following be correct: Primary flow coming out of floor in ac tee off (centre) to pump and top of tee to open vent. This would mean the vent would be on the negative side of the pump. As for the cold feed tee...
  15. W

    MRFC needs help

    Hi Guys, I am with Malahide Rugby Club in Dublin and need some advice ( naturally free as we can't afford to pay for anything at the moment ) My question is: Has anyone Installed/Comissioned/Maintained a HeatMaster ACV HM 100G water heater. Its a large, red, gas fired boiler and at present...
  16. D

    baxi conbi 105e

    can you get a kit for differential on diverter valve,rod not coming out when dhw or ch is called for
  17. L

    primary pipework sizing

    Hello has anybody got any ideas on primary pipework sizing. We have two Worcester Bosch 40CDI boilers cascaded so was wondering what size pipework we would need to the low loss header. I have ordered the Domestic Heating Design Guide (last week) and although they've taken my money Im still...
  18. R

    Hot Water Problem - blockage in primary circuit?

    Morning All On investigating my wife's complaining that the hot water is not as hot as usual it seems that the issue is with the primary circuit. The system is Y plan with vented HW and unsealed CH which is pumped. On demand for HW the primary to the cylinder is well hot but the primary return...
  19. G

    Biasi M90E24s no hot water?????????

    Please help!!! Ive been trying to diagnose a fault with this boiler as i cant get any hot water from it. when going into service mode the lights indicates thats its theres a fault in the primary flow circuit , does this mean the DHW flow sensor???? when reading MI it says that DHW sensor is...
  20. D

    pipework lay outs

    can you have more than one return from the central heating return to the primary return and can it be place'd between radiator returns,open vented fully pumped.