Hi all

i have a baxi 80 he with no hot water or heating it wont fire up at all its gives an error code for a faulty pump we have changed the pump no change with error so we got a new pcb the error still remains, any thoughts on the problem ?

thanks for any help
 
Have u checked the pump dia or m/s?Very rarely does that light mean that the pump is faulty. It's just giving a general area that the fault lies.
 
push the rear flowswitch microswitch up with a insulated screw driver does it now fire?
 
the rear silver microswitch gently push it upwards,if your unsure i will take a photo of mine at home
 
push the silver strip upwards with a screw driver as per photo Photo0015.jpgPhoto0015 (Small).jpg
 
after pushing that switch up if it fires you have a diapragm gone or a blockage in the small orifice under it
 
Status
Not open for further replies.

Reply to no hot water or heating in the Plumbing Jobs | The Job-board area at PlumbersForums.net

Similar plumbing topics

Hi, My current hot water system needs to be replaced. Anyone got any suggestions or can recommend any plumbers around Derrimut area that won't rip me off? An office guy recommended me to apply for government rebates and get it installed through timetosave.com.au. How reliable is this...
Replies
6
Views
307
Hi All I have a leak coming from within my Mira Elite QT shower. It seems to be flowing from behind the switching Control. Any ideas what could be causing this leak. Already Changed the Pump Elbow as one of the clips had popped which was causing a second small leak, Any idea? Is it time to buy...
Replies
0
Views
238
Hi, Can anyone advise as to why the cold water to my bathroom keeps airlocking? This originally happened about 12 months ago and has happened 3-4 times since. It’s an upstairs bathroom, fed from a tank in the attic. The tank is about 8 Meters away and feeds a bath, sink and toilet. The tank...
Replies
9
Views
348
Hi all I'm hoping someone can shine a light on this for me Since our stop tap on the pavement has now been filled with sand for whatever reason, we are relying on our property fitted stopcock (this is outside on our garage wall) Unfortunately turning this to the closed position only reduces...
Replies
3
Views
263
Hi, basic question, any insight much appreciated. Looking to have an outdoor tap in my front porch fed from 15mm pex coming up from suspended floor. Pic 1 is inside porch, pex temporarily clipped to give an idea of pipe placement (ignore shoddy blockwork of booted cowboy builder!), Pic 2 is...
Replies
6
Views
241