Sludge is a semi-solid slurry that can be produced from a range of industrial processes, from water treatment, wastewater treatment or on-site sanitation systems. For example, it can be produced as a settled suspension obtained from conventional drinking water treatment, as sewage sludge from wastewater treatment processes: 23–25  or as fecal sludge from pit latrines and septic tanks. The term is also sometimes used as a generic term for solids separated from suspension in a liquid; this 'soupy' material usually contains significant quantities of 'interstitial' water (between the solid particles). Sludge can consist of a variety of particles, such as animal manure.Industrial wastewater treatment plants produce solids that are also referred to as sludge. This can be generated from biological or physical-chemical processes.
In the activated sludge process for wastewater treatment, the terms "waste activated sludge" and "return activated sludge" are used.
In food processing and beverage-making industries, sludge can have high protein content and other nutrients that can be used for beneficial purposes such as animal feed, thereby avoiding disposal at a landfill.

View More On Wikipedia.org
  1. S

    Low domestic water temp Ideal Logic 24

    Hi all. I have query regarding a DHW issue on a Ideal Logic 24. Boiler is less than two years old. Central heating function works fine. Boiler starts and fires when called for. CH water temp to radiators seems fine. In DHW mode. HW tap on. Water flow ok. Boiler starts and burner indicator on...
  2. S

    British Gas Homecare, Sludge, and boiler diagnosis

    Hello All, I'm hoping someone can help, I have had various boiler problems with my Heatline S24 Combi for awhile, including cutting out. I have British gas home care, but they refused to do anything much unless I pay £800+ for a power flush, due to sludge. I decided to flush it myself, I done...
  3. A

    Viessmann Vitodens 200w Fluctuating hot water....

    My boiler (and entire central heating system) was installed and first used in August 2009. In February 2011 the hot water began fluctuating hot and cold. The boiler still under warranty was repaired by Viessmann with a new heat exchange plate which was blocked with sludge. They replaced this...
  4. P

    Unvented system Luke warm rads

    Some assistance is required I have a unvented system installed on the 3rd floor of a detached house now rads on 2nd and 3rd floor warm up but 1st floor rads are cold/Luke warm can someone advise
  5. A

    cast iron rads & sludge problem

    Hi, I searched the forum and couldn't find this issue discussed before, sorry if it was. I got a new (Sime) gas boiler (with expansion vessel/auto-fill) water central heating system plumbed in 7 years ago to an old 3 storey Georgian terraced house I renovated. It's a mixture of some 100 year...
  6. P

    Sludge on a closed/sealed Combi system

    Hi I have potterton Combi 80 boiler with sealed/closed system that is running on the single pipe (i.e. no separate feed and return pipes). Additionally, the radiators have single outlet on the bottom middle rather than separate inlet and outlet on each bottom side. I have been told by British...
  7. R

    What's the worst case if I leave Sludge Remover in permanently ?

    To cut a long story short, after a BG callout to replace a blocked/scaled pump (didn't see the pump myself so not sure) i was quoted £1200 for a power flush and new pipe work (because it was so sludged apparently) to which i said 'balls' and investigated it myself. After cleaning the expansion...
  8. G

    How long should i leave sludge remover in for?

    hi, i have put Sentinel 1ltr Heavy Duty Sludge Remover into my system last night and was wondering how long it is recommended to leave it in for before draining it again? I have no heat coming from living room, dining room and garage, all radiators have been renewed with bigger and better ones...
  9. P

    PowerFlush and Salamander SESI scale inhibitor

    Hi, I have a Potterton Combi 80 boiler which has been working perfectly until few weeks ago. It started to lock itself out which meant that I had to reset the boiler. Since I have the boiler cover from British Gas, I called them to investigate the issue. What the guy suggested was that it is...
  10. S

    steaming water in F&E tank

    Hi, I have a problem, the only way I can get my heating to stay on (bolier not to trip out) is to remove water from my F&E tank which is steaming hot!!!!! and is constantly overpumping, the only way I can stop this pumping is to disable the pump completley (remove a wire - not great but only...
  11. P

    Sytem recently power flushed,now new pump sucking in air-please help

    Hi all,I am new to this forum. Just to give you a quick low down on what has happened so far. My Mother had a guy round to remove sludge in the central heating pipes which had practically stopped any water flow round the system ,and all but three of her rads remained cold. He refused to power...
  12. L

    F & E Tank, open vented system

    Good Morning I am surprised by the amount of sludge that collects at the bottom of an F & E tank, i would have thought that sludge would have settled more at a low point rather than a high point. Just out of interest is it just sediment being carried around in the circulation of the water and...
  13. W

    Big flange on a sludge cock?

    The flange on this one just isn't sufficient to get a good purchase on. Anyone know where I can find one with a bigger flange?
  14. T

    Stumped - 10mm system

    Hiya I'm having problems with a system that's piped in 10 mm and i wondered if anyone could shed any light. System - a back boiler and on the same floor a hot water cylinder, grundfoss pump, danfoss programmer, stat and MPV. Expansion vessel with system pressure guage atop. Symptoms No...
  15. D

    X400 sludge remover in system with minor leaks

    Hi folks, Heres my situation, I got a bog 19 rad system, some of the radiators have got serious cold spots. The system does lose water pressure but not too fast - 0.5 bar a month. I think there must be small leaks under ground floor where i cannot see. Its been like this for 3 years and is...
  16. L

    Using a sludge buster !!!

    Hi just wondering if anyone can helo using sludge buster todayin my house i have a large volume of water i have downstaires .. 7 big old cast iron rads and 4 new style and upstaires i have 4 old cast iron rads and 7 new style ... What is the best location for theludge machine and will boiker and...
  17. M

    protecting boiler from sludge, magna clean?

    im going to install a magna clean or simlar item on my next boiler change, will be flushed out before hand but which one works best do you think? magna cleans impress me but dont know what there like fitted what do you use?
  18. H

    Sludge in drain

    Hi everyone, In an outside drain, where the bathroom water and water from washing machine goes, there is quite alot of black sludge. There is no smell, and no debris. We have just moved here, and the drains are old, plus doesn't look as if they have been cleaned for years. I've tried a...
  19. P

    ferroli combi dhw issue

    Hi all, Maxima 35C intermittant fault with DHW, CH fine. Tap on water temp get to around 50c then boiler goes off, no fault codes, boiler will then turn back on when been off for a minute or so. Anyone come across this before? cheers
  20. C

    Help needed please ! Vaillant boiler hot water but no heating

    Hi, dont know if I am posting in the right place - but looking for some help if possible please. Have Vaillant combi boiler approx 4 years old. Hot water has been a bit slow in the mornings then comes out brown, then works fine. Electric shower blew at the weekend - think this is the...
Creating content since 2001. Untold Media.

Newest Plumbing Threads

Back
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.

I've Disabled AdBlock