Search the forum,

though

"Even Though" is a song by British trip hop band Morcheeba. The track was the first single from Blood Like Lemonade, the seventh studio album released on 7 June 2010.

View More On Wikipedia.org
  1. R

    Sewage smell from Bathroom, no loo blockage though!

    Hello I have a mystery, my bathroom has a sewage smell appears to get far worse 5pm-9pm. I have plugged my bathroom/sink with plugs and its 100% coming from the toilet. Tried Lugi worlds best plunger, that air gun blaster and 50 buckets of hot water down the toilet for 2-3 days and no joy, the...
  2. M

    Condensate lagged though wall

    Do most people lag 32mm in this case 40mm (1.5inch) as it passes through the wall cavity or just the external pipe? If lagging the pope in the cavity what's best to seal the lagging to the wall with. I'm thinking it wouldn't cement up well?
  3. S

    how to stop tapping / clicking noises from central heating pipes even though there not on?

    Changed from a gravity feed boiler system to a combi boiler and had problems with noisy pipes? About 4 weeks ago now had a new combi boiler installed, and from day 1 had noises from the heating pipes even though not on. Thought I was just up grading to a more modern space saving cost efficient...
  4. A

    Is this pump installed correctly? Pictures keep getting air though the hot water.

    Hello everyone I was wondering if you could help me solve an issue I'm having with air in my hot pipes. I had a positive head pump installed in the airing cupboard as shown in the picture but it would not start without putting the shower head in the bath to increase the pressure. After a month...
  5. B

    Can I have the central heating on even though the grundfos water booster has packed in?

    As per title I have a water booster and it is now broken but I am not sure I can have heating on as it may be topped up by the booster. The booster was for taps and 2 power showers so no no showers and only a trickle from cold less from the hot. Its an oil fired CH system with a condensing...
  6. H

    UFH Problems - pipes hot even though Thermostats are off

    Hope you can help. We have had a problem with our UFH which was ultimately traced to an electrical issue. We have had a new electrical control unit installed and all seemed okay (we had heat!) although we haven't been able to control the heat. The rooms that the pipes run through from the...
  7. Y

    Downstairs radiators not heating even though hot water is getting to them

    Hi there Our 3 bed house had an issue with a diverter valve 3 weeks ago and since getting it replaced 4 of the 5 downstairs radiators are not heating up (2 get a tiny amount of heat, 2 not at all). Upstairs radiators are fine, and the 1 downstairs nearest the boiler is fine too. Pressure is...
  8. U

    Why cold tap handle can still be turned even though valve is closed

    Hi all, I recently replaced the compression type valves on my bathroom basin as the cold one was leaking and also when you tried to turn it on the handle would do almost a complete turn before the valve would open and water came out. Thought this was a knackered circlip and seemed to be so when...
  9. B

    Motorised valve allowing water flow even though spindle closed

    hi. I removed actuator from motorised valve. Spindle at 12 noon so valve should be closed. However hot is flowing through the valve. I can manually turn the spindle about 20 degrees. Is it possible the gland inside is not turning even though spindle is? Many thanks.
  10. D

    ICOS HE15, TADO, hot water only absolutely no heating though

    Would really appreciate thoughts We have an ICOS HE15 (now nearly 9 years old - installed in new build), I installed a tado v1 about 4 years ago, and just upgraded to the v3 model 2 weeks ago. All worked at first, but now I have absolutely no central heating whatsoever. I do have hot water...
  11. A

    pipe repair problem

    I have 4 22mm pipes (hot cold and two central heating) all running together ( no gap between them). someone has put a nail in the second pipe. i can not separate the pipes to cut and couple. And suggestions?
  12. I

    Best adjustable spanner

    Some low life nabbed my tool bag out the van while apprentice left it unlocked while tidyin up at a job had 2 old bahco spanners the ones that where made Sweden in the bag heard bahcos arnt the quality as the used to be so anyone any recomendations ?
  13. Worcester

    Grant Spira Condensing Pellet Boiler

    Anyone got experience of these? We've been looking for a quality pellet boiler at lower cost than the ETA's that we normally install. We have 'value' offerings from a well established UK company with a good reputation, however it isn't a 'name' The advantage of this - it comes with a brand...
  14. R

    £££ though it was a locomotive lol.

    exclusive customers mansion i found this, the top is foot level with the first floor airing cupboard, the rest is in a wall above the aga (breast)with a 2x2 service hatch. how the hell am i going to get it out as its weeping around those top bolts:skep: the house is at least 1920's or older so...
  15. P

    Makita 4.0 combi drill Screwfix £119.99

    http://www.NoLinkingToThis/p/makita-dhp456smij-18v-4-0ah-li-ion-lxt-cordless-combi-drill/6948h I can't afford not to buy it.
  16. R

    Is this fitted correctly

    As above, is this correctly installed or not
  17. A

    Gunk escaping from cyclinder expansion vessel joint

    I have just moved into a new flat which has an unvented hot water cylinder. There is some very disgusting gunky looking stuff around what appears to be a leaking joint/valve going into the expansion vessel. At first I thought it was from a botched repair attempt using some kind of foam sealant...
  18. T

    DHW problem or normal?

    Afternoon everyone, I have a potterton performa 24 and had trouble with the DHW not working, it figured out it was the diverter valve and changed the diaphragm that had a split in it when I tested it before putting the panel back on I noticed the hot water wasn't as hot as it should have been...
  19. U

    Main PCB Cangeout gloworm 35ci

    Hi. The PCB on my gloworm 35CI broke P/N 801915 and the updated model for this is now P/N 2000802038. On changing the PCB, the old PN had a H6 pin which went to the controls board. The new card doesn't have a H6 pin but has a H9 pin instead. Not wanting to bust the board I haven't...
  20. R

    Can I use a Wirquin / Senzo Space Saving Trap on my bath?

    Hi I have just bought this item, Wirquin/Senzo space saving trap, I intended to use it on my bath (the existing piping is in a very awkward position now I have put a new bath in). The illustrations on the instructions are of basins, no mention of a bath. Can I still use it on my bath (please...
Creating content since 2001. Untold Media.

Newest Plumbing Threads

Back
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.

I've Disabled AdBlock