iDEAL remains by far the most popular method for online payments in the Netherlands, well beyond credit card use, and was used for 54% of all Dutch online payments in 2014. The service processed 4.5 million transfers in 2006, 15 million transfers in 2007, 28 million transfers in 2008, 45.4 million in 2009, 68.8 million in 2010, 93.8 million in 2011, 117.2 million in 2012, 142.5 million in 2013, 180.2 million in 2014, 222 million in 2015, 282 million in 2016 and in 2019 655 million transactions. iDEAL is owned by the Dutch organization Currence, which also owned PIN and Chipknip. As of April 2016, the total amount of payments exceeded one billion.The participating banks in iDEAL are ABN AMRO, bunq, Friesland Bank, ING Bank, Knab, Rabobank, Revolut, Triodos Bank, Van Lanschot and De Volksbank. Together they serve the vast majority of the Dutch online banking market.

View More On Wikipedia.org
  1. D

    Ideal Icos HE12 constant F L Code

    Folks Me again I am at my wits end. I want to replace the boiler but I am on my backside and cannot afford to. I have been getting an intermittent F L Code. For around a year. I've had an engineer out 4 times. In that time boiler has had a new PCB, new electrodes, new gaskets, new...
  2. B

    Anyone fitted an Ideal Standard i.life S Basin & Full Pedestal?

    Has anyone fitted an Ideal Standard i.life S 50cm compact washbasin with a matching i.life S & B full pedestal? The basin is T518501 and pedestal is T519901. I have a problem with the pedestal boxed and packaged as the T519901 (but marked T2839 inside as below) - it does not fit and from the...
  3. R

    Ideal Logic Combi ESP1 Time clock jumper link

    Hi looking to remove my existing rf time clock and refit the oem link, but the installer didn’t leave it, anyone point me in the right direction
  4. M_Nash95

    Ideal System 15 losing pressure; pressure dial violently twitching

    Hi there, I am renting at the moment. Our boiler is an Ideal System 15. Within an hour or two of moving in and turning the heat on the boiler lost pressure. Now it loses pressure any time that it is turned on. If the boiler pressure is set below 1.5 bars cold it will lose all pressure in about...
  5. S

    Ideal boiler had the F1 code, so topped pressure up but code persists.

    After researching as much as I can to sort this problem, I keep reading that if your Ideal boiler has an F1 code and the pressure is low, it needs topping up. If it has an F1 code but the pressure is fine, then this indicates a potential pressure sensor fault. What if it was low (completely...
  6. hotpointer

    Ideal Classic FF350 cuts out after 10mins

    Hello , I have an Ideal Classic boiler ff350 which runs for 10 mins before the boiler cuts out. The circ pump keeps running at this time. The Pump and The Three port valve have been checked and the User Stat on the front has been Changed (by a Gas safe engineer) when the Boiler cuts out there is...
  7. T

    Uncoded intermittent ignition fault, Ideal logic heat 18 .

    Ideal logic heat 18. Uncoded intermittent fault near end of days use only. Burner reignites every 15 seconds on and off, but no fault code showing. Boiler isolated and restarted okay but same uncoded fault repeated at end of next day.
  8. J

    Boiler swap Arnold Nottingham

    require my ng heat only 28kw floor standing glow-worm back flue boiler still working (25 years old) replacing with a suitable back flue ng heat only boiler, Location Arnold, Nottingham
  9. F

    Constant Lockout issue with Ideal Concord CXS/SD40/H

    In our Village Hall we have a Ideal Concord CXS/SD40/H central heating boiler. This was installed new when we had an extension built and the existing boiler needed upgrading. The Mechanical Engineers advising the architect insisted that we had a conventional cast iron combustion chamber boiler...
  10. E

    Why does my Ideal logic +30 boiler keep going in to overheat lockout.

    The boiler runs may be 1 or 2 days before erroring. The problem started 3 months ago. The boiler would run blue light on at front an center of boiler. But the pip work out would bearly get warm. The pump should has rust water dripping from Chrome screw hole and the divert value was also...
  11. S

    IDEAL CONCORD FLOOR-STANDING BOILER

    IF any of you plumbers are removing an old Ideal Concorde floor standing boiler please let me know.I need one as spares are many parts are now not available. Many thanks
  12. ian.

    Ideal Heating system filters insulated jacket

    Is it possible to get an insulated jacket for the magnetic filter which is supplied as part of the Ideal Vouge Max (18kw)?
  13. W

    Ideal Logic Combi 35

    Hi all, I've got a bit of a strange issue relating to my Ideal Logic Combi 35 which has recently started displaying a F2 error when trying to use the central heating system. The boiler works fine when using hot water, however when I try to turn on the central heating system the boiler works...
  14. S

    Ideal Logic Combi 30 - pump only keeps activating for 4 mins.

    Hi, As per the thread title, I have an Ideal Logic Combi 30 and I am having a problem with the pump, which keeps activating without any DHW/DCH. When the pump activates, it runs for exactly 4 minutes each time and this can happen as frequently as something like 5 times an hour or as...
  15. G

    Ideal Vogue max 40 noises

    Got an Ideal Vogue 40 Max When its running in the early hours of the morning between 1am and 5am its as quiet as a mouse no issues, when its on in the daytime and evening every now and then its like a ships fog horn sounding off. It is 6 months old and has been doing it from the day it was...
  16. T

    Wire up frost star to Ideal combo 30

    I have an ideal combi 30 boiler and I want to install a frost stat Drayton. I am confused by the wiring because I believe the boiler has no voltage contacts yet all frost stats have 230v. The boiler has two contacts yet the stat has only one switch wire. So confused how to wire up and concerned...
  17. F

    Ideal boiler cycling with Nest & Opentherm

    Hi all, I have an Ideal Logic max 35 and have just connected my Nest thermostat via opentherm. The boiler modulates the water temp fine but as the heat reaches the the target temp on the thermostat, the boiler turns the flame off, keeps the pump running and then every 90-120seconds refires the...
  18. F

    Ideal 25kw combi boiler issue No heating Just hot water

    I wish to thank the boiler guy for disconnecting Hive for me from the combi boiler. You did a wonderful job of cutting off the heating bit, so now I cannot heat the house but still have lovely hot water coming out of the taps, So luckily I have moved my 76-year-old father out of the house. Turns...
  19. D

    Tip - Ideal Vogue Max - Separating DHW and CH Temps

    Hi everyone, My Ideal Vouge Max 26 was installed a few years back, all works fine. Its an S plan setup, but I've always been amazed that the temperature for the water tank and the central heating were the same and 'couldn't' be separated (according to the Ideal registered plumber who installed...
  20. E

    Ideal Logic +18, intermittent fault

    Have an Ideal Logic + 18 with intermittent fault. When on demand the display constantly changes from O to C but burner doesn’t start. Can fix by switching Off then On again, but this only lasts for a day or two. As it’s an intermittent fault I’m reluctant to call out an Engineer. Any ideas?