You are using an out of date browser. It may not display this or other websites correctly. You should upgrade or use an alternative browser.
electrode
An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). An essential part of a battery. It can consist of a variety of materials depending on the type of battery.
The electrophore, invented by Johan Wilcke, was an early version of an electrode used to study static electricity.
Alpha Flame Sensing Electrode part number 3.025192 required asap in Worcestershire. There is a supply issue it appears due to COVID. Please get in touch if you have this part. Many thanks
Does anyone have any experience with resolving an A02 fault?
"Flame present signal with burner off."
Possible cause: electrode or card fault.
It usually starts with an error code regarding no flame after ignition phase and is replaced by A02. I had a gas valve fault being displayed but got rid...
Hi
i have a baxi solo he 24 but has started to melt the electrode wire, i just replaced the electrode and the boiler fired up and worked but it started to melt the wires as it goes into the heat exchanger or probe, has anyone else come across this problem?
Looking for a bit of help on an Ariston 23 mffi microCombi. The burner will run for 5 mins then lockout. If I reset it will run straight away for another couple of minutes. While the burner is running the electrodes are constantly sparking trying to ignite. I changed the detection electrode but...
Hi
Just wondering if anyone knows if there is a replacement gasket for the ideal logic ignition electrodes without buying the full electrodes at £20
Noticed allot start to fall to bits after a while when servicing them.
Also why's one graphite and one fiber.
Thanks
Hi; I've got an Ideal icos HE15 and had a "LF" fault. I have removed the condensate, cleaned filled up with water and refitted. I have replace the Ignition Electrode and the Flame Sensing Electrode. There is no water in the blue tube. There is 235V AC at the Spark Generator and 205V DC at the...
I've never personally removed them on a unica. Other engineer I work with said he doesn't renew the washer on it if he takes it out to clean it or inspect it.
He says sometimes the the washer splits in 2 but he fits it back and analyses it to make sure it's OK.
Surely that's not right? I'd...
hi everyone im new on here but a long term reader of people posts.
i am a gas safe but i do not have 10 posts on the forum yet but im in need of some help with this boiler
it started as a simple leak repair on the flow turbine, far as im ware this is common. then i had to replace electrode...
Hi,
Can anyone tell me the correct method for testing the output from a ignition pcb to the spark electrode ?
I've been roped into looking at my mates Ravenheat 84e tmz. When he creates a demand the pump and fan start but there's no sparking at electrode. I haven't looked at it yet, thought if...
Hey guys
as the cold approaches and i have a few contracts with maintenance and servicing.
i need to do a van stock for boilers fires etc, i know i cant carry it all but could you guys point me in the direction of what would be easy to carry, thermisters, diaphrams etc and for what boilers. I...
HI guys, i have a vaillant ecotec 28e condensing heat only boiler which fires up nicely for about 3 seconds then cuts out. the error code comes up as f4 which is an ignition fault (lockout) went out when lit. i have checked the gas side of things and everything is all good, but im left with the...
can anyone give me a quick hand with this fault-i have a 24 cdi of with ignition fault-slow flashing central heating light, when u reset pump runs and light flashes again any help would be great as i dont have the sequence of operation to hand
Reading on the forum seems a few people are having problems with the ignition on these boilers!!
I'm getting an intermittent E133 fault, so having seen this fault on the baxi duo-tec (normally spark gap on ignition electrode) i removed electrode to check gap and condition, all looked fine...
yep chums its a ferroli optimax he38 GRRR, ok the fault code is A thers a couple of things to do from the install manual.
which i duley did, its got gas, its trying to ignite but i cant hear the piezzo ticking, so im think electrode igniton?
so i check the book and yep its a possible cause, so...
I had an issue with a alpha CB 24 today and could only get the boiler working intermittently. My question is should you get continuity on the electrode lead from either end ?
Hi,
Can anyone help please? 105 HE converted to LPG
On start up the boiler basically goes through all tests and the flame lights but then goes out (tries three times) then flame failure light comes on flashing. The problem is the same on CH and DHW.
Checking the Fault Finding checks the...
Just trying to understand how this works and why it's there.
Every year ignition fails on the boiler (just sits there, tick, tick, tick). The solution seems to be re-position the detection electrode which has bent down.
In really simple terms :) , what's it there for and what does it...
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.