Search the forum,

combi

Combi coupé is a marketing term used by Saab to describe cars with a sloping coupé-like rear hatchback. The term joins the European term "combi" (for an estate car / station wagon) with coupé.The design combines the functionality of a hatchback with the appearance of a fastback. As per a hatchback, the combi coupé incorporates a shared passenger and cargo space.

View More On Wikipedia.org
  1. J

    Storage Combi Boilers

    Do gas fired storage combi boilers store the water at high temperatures like say 75C? and if so do they have a internal TMV?. when the storage runs out presume they then just carry on like any combi boiler?. Do they allways store DHW and not primary water?. Oil fired combis probably are all...
  2. R

    Hot water coming on combi sometimes other times not

    Hi guys thankfully not been needing to com on for a while but could do with a pointer. 2 weeks ago I noticed boiler didn’t fire for hot water in kitchen which is next to boiler and cold main in, it came on after a few seconds longer than norm I thought just a blip, but this weekend and since...
  3. R

    Baxi 228 combi boiler hot water flow rate poor?

    Hi, Just checking I'm not talking rot. Today I visited a house with a Baxi 228 combi boiler. The technical spec for the DHW output is shown in the image. Boiler was installed 27 months ago. Baxi is claiming 13.3 litres @ DT 30. I set the boiler DHW temperature to a high setting. I was...
  4. S

    Baxi Combi 105e: CH lost 1 bar of pressure in a few hours

    Hi everyone Summary is in the title. Found the boiler was at 0.5 bar earlier today so topped up to 1.5 bar. Checked before bed and its back to 0.5 bar. There are no signs of a leak around any radiators nor any suspicious water damage on the downstairs ceiling. Before I rip up all the flooring...
  5. S

    Ideal Logic Combi 30 - pump only keeps activating for 4 mins.

    Hi, As per the thread title, I have an Ideal Logic Combi 30 and I am having a problem with the pump, which keeps activating without any DHW/DCH. When the pump activates, it runs for exactly 4 minutes each time and this can happen as frequently as something like 5 times an hour or as...
  6. P

    Mystery Worcester Bosch Combi Status Code 265.

    Can anyone please explain why my 12 month old WB Greenstar 28CDi Compact ErP Combi with fascia mounted Comfort ll room stat continually stalls with a 265 Status Code "Stand-by mode forced due to energy transfer limit", causing it to take twice as long to reach the set room temperature than it...
  7. P

    URGENT Baxi Duo-Tec Combi 33 HE DHW Fault

    Hello, Looking for someone who can please help solve this problem and fix our boiler. Staffs area. CH seems fine. Boiler can be coaxed into full burn with the fan spinning at full speed, so I think everythings fine on the gas/air/flue/condensate side of things. If there is DHW demand on the...
  8. J

    unvented cylinder v combi store

    Hi all, My customer is renovating a house. Complete renovation of the plumbing. It's a three-bed house for a young family of 3. It will have one main bathroom (bath and maybe an over-bath shower), plus two shower ensuites. I have yet to check the incoming water pressures/flow rates to the...
  9. F

    Ideal 25kw combi boiler issue No heating Just hot water

    I wish to thank the boiler guy for disconnecting Hive for me from the combi boiler. You did a wonderful job of cutting off the heating bit, so now I cannot heat the house but still have lovely hot water coming out of the taps, So luckily I have moved my 76-year-old father out of the house. Turns...
  10. D

    Worcester Greenstar 30 Cdi Combi loss of CH & HW -overheating

    Hi all, 12 year old boiler, regularly serviced working fine, then wife turned on hot water and it stopped working. Same then with CH. Left it for a while worked and then stopped again. I looked at it when got home and when run water boilersstarts up, temp rises and then it cuts out. Same with...
  11. J

    Vaillant Ecotec Exclusive Green IQ 835 combi modulation problem

    Hello, We got a Vaillant Ecotec Exclusive Green IQ 835 combi boiler in November 2021 as we wanted the most efficient boiler that modulated really well, especially for heating. Two weeks after the installation, the heating engineer needed to recalibrate the boiler and after that we started...
  12. iCannon

    Flow issues with a Potterton Heatmax Combi 28 HE

    Hi I have a Potterton Heatmax Combi 28 HE that was installed in 2014. Over the past year or so it has slowly had more trouble heating distant radiators. It was serviced in February 2022 and given a clean bill of health, however since then it now only heats the two nearest radiators and at a...
  13. G

    Firebird Combi CH Not working

    Evening Gents. That time of year again the wife has demanded the CH Be turned on. However, im having an issue with it - It simply isnt turning on. The LED On the front panel illuminates to suggest the CH Has been turned on by the boiler, but nothing happens. The HW works perfectly normal. If...
  14. M

    Help with leaking boiler flue on baxi neta tec combi ga24?

    Hi, I've been having trouble with my boiler leaking for months. We thought we'd fixed it last winter as haven't had any trouble throughout the summer but in the last week or 2 it's leaked again, we had several people out to look at it but no one fixed it. Tonight we've had someone else look and...
  15. P

    Constant head pump for old combi?

    Hello forum, 1st time here. The Grundfos 3-speed pump in a Worcester Heatslave 15/19 oil combi boiler is on its way out. The boiler is old but in v good nick. The network is trunk/branches. All rads (but one) have TRVs. Pump is set on max, which seems to be what it needs when supplying all...
  16. D

    firebird enviromax combi lock out

    Hi. I have a firebird enviromax combi boiler. each time it turns off the motor on the riello burner keeps running for a while then the whole thing goes into lock out. flashing green and red. shouldn't the motor turn off straight away? I'm also getting pressure building up while it's running...
  17. M

    Choosing Combi with Modulation and Smart Controls

    Hi all I wonder if anyone could offer some advice. I’m looking for a new combi and thought I may as well upgrade to smart controls if we have to change it. I’ve pretty much worked out that I need a boiler with decent modulation (10:1 or as near to it would be great). I’d like a stainless heat...
  18. R

    Advice on Combi Boiler

    Hello - I was hoping for some advice and opinions on a new combi boiler I currently have a 3 bed semi with a myson orion boiler (it isnt a combi) - the boiler was installed around 1989, hasn't given any problems and is still working fine. Due to the increase in gas prices it is time to change...
  19. E

    EPH COMBI PACK 4 to ida

    Hi there Advice needed having a eph combi pack 4 fitted to my ideal vogue c40 gen 2 boiler 2017 model the wiring change on post 2019 boilers. Do I need a separate power supply for the reciever or can this be powered from the boiler. It will be connected via open therm. Many thanks
  20. K

    Error E119 Potterton Combi Gold 24E

    I'm getting an e119 error which I assume is low water pressure. I'm turning the 2 valves that I think should increase pressure but I'm not getting anything. Any ideas?