Discuss Ideal Heat 15 - repressurise in the Central Heating Forum area at PlumbersForums.net

Messages
8
Hi. I've got an Ideal Heat 15 system and I've noticed a few of my rads need bleeding. I've located the pressure gauge which is above my cylinder and is already reading only 0.5 bar and if I bleed the rads, this pressure is going to drop further.

I've located what appears to be the filling point (it's tagged as such) but when I turn the valve, nothing happens.

Any advice would be greatly appreciated.
IMG_20200108_171140284.jpg
IMG_20200108_175059691.jpg
IMG_20200108_175115556.jpg
IMG_20200108_175136147.jpg
 
Did you open both eg black lever one

and the screwdriver slot on the other end (not the one above the black lever)
 
Open up that flat head valve on the flexi end entering the system with a large flat head screwdriver and then turn the black lever 1/4 of a turn. When system has reached pressure close and bleed the rads, top up again as needed
 
Have you had your cylinder serviced as it requires it annually.
Need a G3 registered engineer.
If it's been serviced properly then that would of been sorted for you
 

Reply to Ideal Heat 15 - repressurise in the Central Heating Forum area at PlumbersForums.net

Similar plumbing topics

I have been facing central heating low pressure on unvented hot water RM Cylinders but can't see any leak on the PRV, expansion vessels and plasterboard celling. I have got unvented pressurized RM Cylinders hot water system with 27KW Worchester gas boiler with expansion vessels . When...
Replies
2
Views
436
losing pressure
L
I was sent an engineer by Ideal Heating to fix a problem with my system. When he left he drove over a pot of sealing compound (which must have dropped out of his van) on my shared drive. My neighbour pointed it out to me since he was parked in her space. I tried to remove it with water and...
Replies
10
Views
613
Got fd code on Ideal Logic Heat 15. Had two plumbers out and no joy. It’s had a new water flow sensor, flush with sentinel x800 and refurbished grundfos water pump. Boiler tries to light and water pump power light comes on but goes off immediately and boiler flashes fd again. It’s heat only so I...
Replies
16
Views
524
Can central heating / gas engineer expert help me with below issue. During winter time only, I have been having issue with low pressure or pressure dropping with unvented hot water cylinder system. During summer time there is no usage of central heating so the pressure at unvented system is not...
Replies
0
Views
558
Hi. I am unable to repressurise my boiler after draining to remove some pipes. I have done this several times before it was moved into the loft. The guy who moved boiler is stumped and recons boiler is faulty. It's only 3 years old. Only a small amount of water enters boiler before it stops...
Replies
6
Views
1K